xhci: Reset Renesas uPD72020x USB controller for 32-bit DMA issue
The Renesas uPD72020x XHCI controller seems to suffer from a really annoying bug, where it may retain some of its DMA programming across a XHCI reset, and despite the driver correctly programming new DMA addresses. This is visible if the device has been using 64-bit DMA addresses, and is then switched to using 32-bit DMA addresses. The top 32 bits of the address (now zero) are ignored are replaced by the 32 bits from the *previous* programming. Sticking with 64-bit DMA always works, but doesn't seem very appropriate. A PCI reset of the device restores the normal functionality, which is done at probe time. Unfortunately, this has to be done before any quirk has been discovered, hence the intrusive nature of the fix. Tested-by: Ard Biesheuvel <ard.biesheuvel@linaro.org> Signed-off-by: Marc Zyngier <marc.zyngier@arm.com> Signed-off-by: Bjorn Helgaas <bhelgaas@google.com> Acked-by: Mathias Nyman <mathias.nyman@linux.intel.com> CC: stable@vger.kernel.org # v4.11+
Showing
Please register or sign in to comment