Commit 9f08ef59 authored by Paulo Zanoni's avatar Paulo Zanoni Committed by Daniel Vetter

drm/i915: use the correct register when turning VDD off

That explains why I was seeing 2 consecutive "Turning eDP VDD off"
messages.

Regression introduced by:
    commit bf13e81b
    Author: Jani Nikula <jani.nikula@intel.com>
    Date:   Fri Sep 6 07:40:05 2013 +0300
        drm/i915: add support for per-pipe power sequencing on vlv
Signed-off-by: default avatarPaulo Zanoni <paulo.r.zanoni@intel.com>
Reviewed-by: default avatarJani Nikula <jani.nikula@intel.com>
Signed-off-by: default avatarDaniel Vetter <daniel.vetter@ffwll.ch>
parent 1ad577ac
......@@ -1125,8 +1125,8 @@ static void ironlake_panel_vdd_off_sync(struct intel_dp *intel_dp)
pp = ironlake_get_pp_control(intel_dp);
pp &= ~EDP_FORCE_VDD;
pp_stat_reg = _pp_ctrl_reg(intel_dp);
pp_ctrl_reg = _pp_stat_reg(intel_dp);
pp_ctrl_reg = _pp_ctrl_reg(intel_dp);
pp_stat_reg = _pp_stat_reg(intel_dp);
I915_WRITE(pp_ctrl_reg, pp);
POSTING_READ(pp_ctrl_reg);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment