scsi: zfcp: fix wrong data and display format of SFP+ temperature
When implementing support for retrieval of local diagnostic data from the FCP channel, the wrong data format was assumed for the temperature of the local SFP+ connector. The Fibre Channel Link Services (FC-LS-3) specification is not clear on the format of the stored integer, and only after consulting the SNIA specification SFF-8472 did we realize it is stored as two's complement. Thus, the used data and display format is wrong, and highly misleading for users when the temperature should drop below 0°C (however unlikely that may be). To fix this, change the data format in `struct fsf_qtcb_bottom_port` from unsigned to signed, and change the printf format string used to generate `zfcp_sysfs_adapter_diag_sfp_temperature_show()` from `%hu` to `%hd`. Link: https://lore.kernel.org/r/d6e3be5428da5c9490cfff4df7cae868bc9f1a7e.1582039501.git.bblock@linux.ibm.com Fixes: a10a61e8 ("scsi: zfcp: support retrieval of SFP Data via Exchange Port Data") Fixes: 6028f7c4 ("scsi: zfcp: introduce sysfs interface for diagnostics of local SFP transceiver") Cc: <stable@vger.kernel.org> # 5.5+ Reviewed-by: Jens Remus <jremus@linux.ibm.com> Reviewed-by: Fedor Loshakov <loshakov@linux.ibm.com> Reviewed-by: Steffen Maier <maier@linux.ibm.com> Signed-off-by: Benjamin Block <bblock@linux.ibm.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Showing
Please register or sign in to comment