staging: comedi: das1800: allow setting the external trigger polarity
The external pin TGIN can be used to start and/or stop the analog input command. Currently the driver only supports negative edge polarity for this signal. Add support to allow the user to select positive edge polarity using the CR_INVERT flag. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>