Staging: comedi: pcl818: Correct AI scan counting and channel checks
For AI commands, the scan counter should be updated after every scan. It was being updated after every sample except for DMA mode where it was being updated after every repeated segment of the channel list. Also AI commands with multiple channels were being terminated with an error prematurely except in DMA mode. This was because the driver was comparing channel numbers received from the hardware (combined with the sample value) with the expected channel numbers to check for a "channel dropout". This test was failing incorrectly because the driver was not keeping the current position within the (repeated segment of the) channel list up to date. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>