Commit b8b3de22 authored by Gavin Shan's avatar Gavin Shan Committed by Benjamin Herrenschmidt

powerpc/eeh: Don't check RTAS token to get PE addr

RTAS token "ibm,get-config-addr-info" or ibm,get-config-addr-info2"
are used to retrieve the PE address according to PCI address, which
made up of domain/bus/slot/function. If we don't have those 2 tokens,
the domain/bus/slot/function would be used as the address for EEH
RTAS operations. Some older f/w might not have those 2 tokens and
that blocks the EEH functionality to be initialized. It was introduced
by commit e2af155c ("powerpc/eeh: pseries platform EEH initialization").

The patch skips the check on those 2 tokens so we can bring up EEH
functionality successfully. And domain/bus/slot/function will be
used as address for EEH RTAS operations.

Cc: <stable@vger.kernel.org> # v3.4+
Reported-by: default avatarRobert Knight <knight@princeton.edu>
Signed-off-by: default avatarGavin Shan <shangw@linux.vnet.ibm.com>
Tested-by: default avatarRobert Knight <knight@princeton.edu>
Signed-off-by: default avatarBenjamin Herrenschmidt <benh@kernel.crashing.org>
parent c5df457f
......@@ -83,7 +83,11 @@ static int pseries_eeh_init(void)
ibm_configure_pe = rtas_token("ibm,configure-pe");
ibm_configure_bridge = rtas_token("ibm,configure-bridge");
/* necessary sanity check */
/*
* Necessary sanity check. We needn't check "get-config-addr-info"
* and its variant since the old firmware probably support address
* of domain/bus/slot/function for EEH RTAS operations.
*/
if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) {
pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n",
__func__);
......@@ -102,12 +106,6 @@ static int pseries_eeh_init(void)
pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n",
__func__);
return -EINVAL;
} else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE &&
ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) {
pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and "
"<ibm,get-config-addr-info> invalid\n",
__func__);
return -EINVAL;
} else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) {
pr_warning("%s: RTAS service <ibm,configure-pe> and "
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment