Commit c2ce5fb3 authored by Joel Fernandes's avatar Joel Fernandes Committed by Tony Lindgren

ARM: OMAP: DRA7xx: Make L4SEC clock domain SWSUP only

Using HWSUP for l4sec clock domain is causing warnings in HWMOD code for
DRA7. Based on some observations, once the clock domain goes into an IDLE
state (because of no activity etc), the IDLEST for the module goes to '0x2'
value which means Interface IDLE condition. So far so go, however once the
MODULEMODE is set to disabled for the particular IP, the IDLEST for the
module should go to '0x3', per the HW AUTO IDLE protocol. However this is
not observed and there is no reason per the protocl for the transition to
not happen. This could potentially be a bug in the HW AUTO state-machine.

Work around for this is to use SWSUP only for the particular clockdomain.
With this all the transitions of IDLEST happen correctly and warnings
don't occur.
Signed-off-by: default avatarJoel Fernandes <joelf@ti.com>
Signed-off-by: default avatarLokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: default avatarTero Kristo <t-kristo@ti.com>
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
parent 7a825cc8
......@@ -409,7 +409,7 @@ static struct clockdomain l4sec_7xx_clkdm = {
.dep_bit = DRA7XX_L4SEC_STATDEP_SHIFT,
.wkdep_srcs = l4sec_wkup_sleep_deps,
.sleepdep_srcs = l4sec_wkup_sleep_deps,
.flags = CLKDM_CAN_HWSUP_SWSUP,
.flags = CLKDM_CAN_SWSUP,
};
static struct clockdomain l3main1_7xx_clkdm = {
......