Commit cb5ae053 authored by Eliad Peller's avatar Eliad Peller Committed by Luciano Coelho

wl12xx: configure rates when working in ibss mode

When working in ibss mode, we don't configure rate policy per station
(as we use the same link for multiple stations), so currently the
1mb/s rate is being used.

Instead, configure the firmware to use the whole 11b rates by default.
Signed-off-by: default avatarEliad Peller <eliad@wizery.com>
Signed-off-by: default avatarLuciano Coelho <coelho@ti.com>
parent 30df14d0
......@@ -516,6 +516,13 @@ struct conf_rx_settings {
#define CONF_TX_AP_DEFAULT_MGMT_RATES (CONF_HW_BIT_RATE_1MBPS | \
CONF_HW_BIT_RATE_2MBPS | CONF_HW_BIT_RATE_5_5MBPS)
/*
* Default rates for working as IBSS. use 11b rates
*/
#define CONF_TX_IBSS_DEFAULT_RATES (CONF_HW_BIT_RATE_1MBPS | \
CONF_HW_BIT_RATE_2MBPS | CONF_HW_BIT_RATE_5_5MBPS | \
CONF_HW_BIT_RATE_11MBPS);
struct conf_tx_rate_class {
/*
......
......@@ -2509,6 +2509,24 @@ static void wl1271_bss_info_changed_ap(struct wl1271 *wl,
}
}
if (changed & BSS_CHANGED_IBSS) {
wl1271_debug(DEBUG_ADHOC, "ibss_joined: %d",
bss_conf->ibss_joined);
if (bss_conf->ibss_joined) {
u32 rates = bss_conf->basic_rates;
wl->basic_rate_set = wl1271_tx_enabled_rates_get(wl,
rates);
wl->basic_rate = wl1271_tx_min_rate_get(wl);
/* by default, use 11b rates */
wl->rate_set = CONF_TX_IBSS_DEFAULT_RATES;
ret = wl1271_acx_sta_rate_policies(wl);
if (ret < 0)
goto out;
}
}
ret = wl1271_bss_erp_info_changed(wl, bss_conf, changed);
if (ret < 0)
goto out;
......