rtc: hym8563: Read the valid flag directly instead of caching it
The RTC has a valid bit in the seconds register that indicates whether power was lost since the pevious time set. This bit is currently read once at probe time, cached and updated with set_time. Howeever, caching the bit may prevent detecting power loss at runtime (which can happen if the RTC's supply is distinct from the the platform's). Writing the seconds register when setting time will clear the bit, so there should be no downside in reading the bit directly instead of caching it. Signed-off-by: Paul Kocialkowski <paul.kocialkowski@bootlin.com> Link: https://lore.kernel.org/r/20191212153111.966923-2-paul.kocialkowski@bootlin.comSigned-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>