thermal: hwmon: Properly report critical temperature in sysfs
commit f37fabb8 upstream. In the critical sysfs entry the thermal hwmon was returning wrong temperature to the user-space. It was reporting the temperature of the first trip point instead of the temperature of critical trip point. For example: /sys/class/hwmon/hwmon0/temp1_crit:50000 /sys/class/thermal/thermal_zone0/trip_point_0_temp:50000 /sys/class/thermal/thermal_zone0/trip_point_0_type:active /sys/class/thermal/thermal_zone0/trip_point_3_temp:120000 /sys/class/thermal/thermal_zone0/trip_point_3_type:critical Since commit e68b16ab ("thermal: add hwmon sysfs I/F") the driver have been registering a sysfs entry if get_crit_temp() callback was provided. However when accessed, it was calling get_trip_temp() instead of the get_crit_temp(). Fixes: e68b16ab ("thermal: add hwmon sysfs I/F") Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>