Commit eb03610a authored by Peter Meerwald's avatar Peter Meerwald Committed by Jonathan Cameron

iio: Correct description how to convert microtesla to gauss

this just fixes the comment; however, I'm not sure if the driver reports
measurements correctly; the raw values are 0.3 uT / LSB; IIO is supposed
to report magnetic fields in Gauss, so the scale should be around 1/300
(ignoring ASA) -- but value and scale are returned as VAL_INT
Signed-off-by: default avatarPeter Meerwald <pmeerw@pmeerw.net>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
parent 20728759
......@@ -263,7 +263,7 @@ static int ak8975_setup(struct i2c_client *client)
*
* HuT = H * 1229/4096, or roughly, 3/10.
*
* Since 1uT = 100 gauss, our final scale factor becomes:
* Since 1uT = 0.01 gauss, our final scale factor becomes:
*
* Hadj = H * ((ASA + 128) / 256) * 3/10 * 100
* Hadj = H * ((ASA + 128) * 30 / 256
......
Markdown is supported