Commit f99cd20e authored by Hayes Wang's avatar Hayes Wang Committed by David S. Miller

r8152: reset flow control patch when linking on for RTL8153B

When linking ON, the patch of flow control has to be reset. This
makes sure the patch works normally.
Signed-off-by: default avatarHayes Wang <hayeswang@realtek.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent a3914272
......@@ -2865,6 +2865,17 @@ static int rtl8153_enable(struct r8152 *tp)
r8153_set_rx_early_timeout(tp);
r8153_set_rx_early_size(tp);
if (tp->version == RTL_VER_09) {
u32 ocp_data;
ocp_data = ocp_read_word(tp, MCU_TYPE_USB, USB_FW_TASK);
ocp_data &= ~FC_PATCH_TASK;
ocp_write_word(tp, MCU_TYPE_USB, USB_FW_TASK, ocp_data);
usleep_range(1000, 2000);
ocp_data |= FC_PATCH_TASK;
ocp_write_word(tp, MCU_TYPE_USB, USB_FW_TASK, ocp_data);
}
return rtl_enable(tp);
}
......