Commit fab303ba authored by Krzysztof Kozlowski's avatar Krzysztof Kozlowski Committed by Greg Kroah-Hartman

thermal: hwmon: Properly report critical temperature in sysfs

commit f37fabb8 upstream.

In the critical sysfs entry the thermal hwmon was returning wrong
temperature to the user-space.  It was reporting the temperature of the
first trip point instead of the temperature of critical trip point.

For example:
	/sys/class/hwmon/hwmon0/temp1_crit:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_temp:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_type:active
	/sys/class/thermal/thermal_zone0/trip_point_3_temp:120000
	/sys/class/thermal/thermal_zone0/trip_point_3_type:critical

Since commit e68b16ab ("thermal: add hwmon sysfs I/F") the driver
have been registering a sysfs entry if get_crit_temp() callback was
provided.  However when accessed, it was calling get_trip_temp() instead
of the get_crit_temp().

Fixes: e68b16ab ("thermal: add hwmon sysfs I/F")
Signed-off-by: default avatarKrzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 05bc2071
......@@ -98,7 +98,7 @@ temp_crit_show(struct device *dev, struct device_attribute *attr, char *buf)
int temperature;
int ret;
ret = tz->ops->get_trip_temp(tz, 0, &temperature);
ret = tz->ops->get_crit_temp(tz, &temperature);
if (ret)
return ret;
......