- 22 Mar, 2012 40 commits
-
-
Alex Elder authored
Nothing too big here. - define the size of the buffer used for consuming ignored incoming data using a symbolic constant - simplify the condition determining whether to unmap the page in write_partial_msg_pages(): do it for crc but not if the page is the zero page Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Make a small change in the code that counts down kvecs consumed by a ceph_tcp_sendmsg() call. Same functionality, just blocked out a little differently. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Move blocks of code out of loops in read_partial_message_section() and read_partial_message(). They were only was getting called at the end of the last iteration of the loop anyway. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Calculate CRC in a separate step from rearranging the byte order of the result, to improve clarity and readability. Use offsetof() to determine the number of bytes to include in the CRC calculation. In read_partial_message(), switch which value gets byte-swapped, since the just-computed CRC is already likely to be in a register. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Change the name (and type) of a few CRC-related Boolean local variables so they contain the word "do", to distingish their purpose from variables used for holding an actual CRC value. Note that in the process of doing this I identified a fairly serious logic error in write_partial_msg_pages(): the value of "do_crc" assigned appears to be the opposite of what it should be. No attempt to fix this is made here; this change preserves the erroneous behavior. The problem I found is documented here: http://tracker.newdream.net/issues/2064Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Many ceph-related Boolean options offer the ability to both enable and disable a feature. For all those that don't offer this, add a new option so that they do. Note that ceph_show_options()--which reports mount options currently in effect--only reports the option if it is different from the default value. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
This gathers a number of very minor changes: - use %hu when formatting the a socket address's address family - null out the ceph_msgr_wq pointer after the queue has been destroyed - drop a needless cast in ceph_write_space() - add a WARN() call in ceph_state_change() in the event an unrecognized socket state is encountered - rearrange the logic in ceph_con_get() and ceph_con_put() so that: - the reference counts are only atomically read once - the values displayed via dout() calls are known to be meaningful at the time they are formatted Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
There is no real need for ceph_tcp_connect() to return the socket pointer it creates, since it already assigns it to con->sock, which is visible to the caller. Instead, have it return an error code, which tidies things up a bit. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Define a helper function to perform various cleanup operations. Use it both in the exit routine and in the init routine in the event of an error. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The messenger workqueue has no need to be public. So give it static scope. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Encapsulate the operation of adding a new chunk of data to the next open slot in a ceph_connection's out_kvec array. Also add a "reset" operation to make subsequent add operations start at the beginning of the array again. Use these routines throughout, avoiding duplicate code and ensuring all calls are handled consistently. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
One of the arguments to prepare_write_connect() indicates whether it is being called immediately after a call to prepare_write_banner(). Move the prepare_write_banner() call inside prepare_write_connect(), and reinterpret (and rename) the "after_banner" argument so it indicates that prepare_write_connect() should *make* the call rather than should know it has already been made. This was split out from the next patch to highlight this change in logic. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Currently an rbd device's id is released when it is removed, but it is done before the code is run to clean up sysfs-related files (such as /sys/bus/rbd/devices/1). It's possible that an rbd is still in use after the rbd_remove() call has been made. It's essentially the same as an active inode that stays around after it has been removed--until its final close operation. This means that the id shows up as free for reuse at a time it should not be. The effect of this was seen by Jens Rehpoehler, who: - had a filesystem mounted on an rbd device - unmapped that filesystem (without unmounting) - found that the mount still worked properly - but hit a panic when he attempted to re-map a new rbd device This re-map attempt found the previously-unmapped id available. The subsequent attempt to reuse it was met with a panic while attempting to (re-)install the sysfs entry for the new mapped device. Fix this by holding off "putting" the rbd id, until the rbd_device release function is called--when the last reference is finally dropped. Note: This fixes: http://tracker.newdream.net/issues/1907Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Here is another set of small code tidy-ups: - Define SECTOR_SHIFT and SECTOR_SIZE, and use these symbolic names throughout. Tell the blk_queue system our physical block size, in the (unlikely) event we want to use something other than the default. - Delete the definition of struct rbd_info, which is never used. - Move the definition of dev_to_rbd() down in its source file, just above where it gets first used, and change its name to dev_to_rbd_dev(). - Replace an open-coded operation in rbd_dev_release() to use dev_to_rbd_dev() instead. - Calculate the segment size for a given rbd_device just once in rbd_init_disk(). - Use the '%zd' conversion specifier in rbd_snap_size_show(), since the value formatted is a size_t. - Switch to the '%llu' conversion specifier in rbd_snap_id_show(). since the value formatted is unsigned. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
A few blocks of code are rearranged a bit here: - In rbd_header_from_disk(): - Don't bother computing snap_count until we're sure the on-disk header starts with a good signature. - Move a few independent lines of code so they are *after* a check for a failed memory allocation. - Get rid of unnecessary local variable "ret". - Make a few other changes in rbd_read_header(), similar to the above--just moving things around a bit while preserving the functionality. - In rbd_rq_fn(), just assign rq in the while loop's controlling expression rather than duplicating it before and at the end of the loop body. This allows the use of "continue" rather than "goto next" in a number of spots. - Rearrange the logic in snap_by_name(). End result is the same. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Once rbd_bus_type is registered, it allows an "add" operation via the /sys/bus/rbd/add bus attribute, and adding a new rbd device that way establishes a connection between the device and rbd_root_dev. But rbd_root_dev is not registered until after the rbd_bus_type registration is complete. This could (in principle anyway) result in an invalid state. Since rbd_root_dev has no tie to rbd_bus_type we can reorder these two initializations and never be faced with this scenario. In addition, unregister the device in the event the bus registration fails at module init time. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The mon_addrs buffer in rbd_add is used to hold a copy of the monitor IP addresses supplied via /sys/bus/rbd/add. That is passed to rbd_get_client(), which never modifies it (nor do any of the functions it gets passed to thereafter)--the mon_addr parameter to rbd_get_client() is a pointer to constant data, so it can't be modifed. Furthermore, rbd_get_client() has the length of the mon_addrs buffer and that is used to ensure nothing goes beyond its end. Based on all this, there is no reason that a buffer needs to be used to hold a copy of the mon_addrs provided via /sys/bus/rbd/add. Instead, the location within that passed-in buffer can be provided, along with the length of the "token" therein which represents the monitor IP's. A small change to rbd_add_parse_args() allows the address within the buffer to be passed back, and the length is already returned. This now means that, at least from the perspective of this interface, there is no such thing as a list of monitor addresses that is too long. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
The argument parsing routine already computes the size of the mon_addrs buffer it extracts from the "command." Pass it to the caller so it can use it to provide the length to rbd_get_client(). Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
This is a bit gratuitous, but there are a few things that can be verified at build time rather than run time, so do that. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Make use of a few simple helper routines to parse the arguments rather than sscanf(). This will treat both missing and too-long arguments as invalid input (rather than silently truncating the input in the too-long case). In time this can also be used by rbd_add() to use the passed-in buffer in place, rather than copying its contents into new buffers. It appears to me that the sscanf() previously used would not correctly handle a supplied snapshot--the two final "%s" conversion specifications were not separated by a space, and I'm not sure how sscanf() handles that situation. It may not be well-defined. So that may be a bug this change fixes (but I didn't verify that). The sizes of the mon_addrs and options buffers are now passed to rbd_add_parse_args(), so they can be supplied to copy_token(). Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Move the code that parses the arguments provided to rbd_add() (which are supplied via /sys/bus/rbd/add) into a separate function. Also rename the "mon_dev_name" variable in rbd_add() to be "mon_addrs". The variable represents a list of one or more comma-separated monitor IP addresses, each with an optional port number. I think "mon_addrs" captures that notion a little better. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
If a couple pointers are initialized to NULL then a single "out_nomem" label can be used for all of the memory allocation failure cases in rbd_add(). Also, get rid of the "irc" local variable there. There is no real need for "rc" to be type ssize_t, and it can be used in the spot "irc" was. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The length of the string containing the monitor address specification(s) will never exceed the length of the string passed in to rbd_add(). The same holds true for the ceph + rbd options string. So reduce the amount of memory allocated for these to that length rather than the maximum (1024 bytes). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_get_client() currently returns an error code. It assigns the rbd_client field of the rbd_device structure it is passed if successful. Instead, have it return the created rbd_client structure and return a pointer-coded error if there is an error. This makes the assignment of the client pointer more obvious at the call site. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Here are a few very simple cleanups: - Add a "RBD_" prefix to the two driver name string definitions. - Move the definition of struct rbd_request below struct rbd_req_coll to avoid the need for an empty declaration of the latter. - Move and group the definitions of rbd_root_dev_release() and rbd_root_dev, as well as rbd_bus_type and rbd_bus_attrs[], close to the top of the file. Arrange the latter so rbd_bus_type.bus_attrs can be initialized statically. - Get rid of an unnecessary local variable in rbd_open(). - Rework some hokey logic in rbd_bus_add_dev(), so the value of "ret" at the end is either 0 or -ENOENT to avoid the need for the code duplication that was there. - Rename a goto target in rbd_add(). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The spinlock used to protect rbd_client_list is named "node_lock". Rename it to "rbd_client_list_lock" to make it more obvious what it's for. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_client_create() is only called in one place, move the acquisition of the mutex around that call inside that function. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_get_client() is only called in one place, move the acquisition of the mutex around that call inside that function. Furthermore, within rbd_get_client(), it appears the mutex only needs to be held while calling rbd_client_create(). (Moving the lock inside that function will wait for the next patch.) Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
In rbd_get_client(), if a client is reused, a number of things get done while still holding the list lock unnecessarily. This just moves a few things that need no lock protection outside the lock. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
It used to be that selecting a new unique identifier for an added rbd device required searching all existing ones to find the highest id is used. A recent change made that unnecessary, but made it so that id's used were monotonically non-decreasing. It's a bit more pleasant to have smaller rbd id's though, and this change makes ids get allocated as they were before--each new id is one more than the maximum currently in use. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The only time entries are added to or removed from the global rbd_dev_list is exactly when a "put" or "get" operation is being performed on a rbd_dev's id. So just move the list management code into get/put routines. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The rbd_dev_list is just a simple list of all the current rbd_devices. Using the ctl_mutex as a concurrency guard is overkill. Instead, use a spinlock for that specific purpose. This also reduces the window that the ctl_mutex needs to be held in rbd_add(). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
In order to select a new unique identifier for an added rbd device, the list of all existing ones is searched and a value one greater than the highest id is used. The list search can be avoided by using an atomic variable that keeps track of the current highest id. Using a get/put model for id's we can limit the boundless growth of id numbers a bit by arranging to reuse the current highest id once it gets released. Add these calls to "put" the id when an rbd is getting removed. Note that this changes the pattern of device id's used--new values will never be below the highest one seen so far (even if there exists an unused lower one). I assert this is OK because the key property of an rbd id is its uniqueness, not its magnitude. Regardless, a follow-on patch will restore the old way of doing things, I just think this commit just makes the incremental change to atomics a little easier to understand. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Move the loop that finds a new unique rbd id to use into its own helper function. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Josh Durgin authored
There's already a constant for this anyway. Since rbd_header_set_snap() is only used to set the rbd device snap_name field, just do that within that function rather than having it take the snap_name as an argument. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net> v2: Changed interface rbd_header_set_snap() so it explicitly updates the snap_name in the rbd_device. Also added a BUILD_BUG_ON() to verify the size of the snap_name field is sufficient for SNAP_HEAD_NAME.
-
Alex Elder authored
The rbd_device structure maintains a duplicate copy of the ceph_client pointer maintained in its rbd_client structure. There appears to be no good reason for this, and its presence presents a risk of them getting out of synch or otherwise misused. So kill it off, and use the rbd_client copy only. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
ceph_parse_options() takes the address of a pointer as an argument and uses it to return the address of an allocated structure if successful. With this interface is not evident at call sites that the pointer is always initialized. Change the interface to return the address instead (or a pointer-coded error code) to make the validity of the returned pointer obvious. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Some minor cleanups in "drivers/block/rbd.c: - Use the more meaningful "RBD_MAX_OBJ_NAME_LEN" in place if "96" in the definition of RBD_MAX_MD_NAME_LEN. - Use DEFINE_SPINLOCK() to define and initialize node_lock. - Drop a needless (char *) cast in parse_rbd_opts_token(). - Make a few minor formatting changes. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
This patch just rearranges a few bits of code to make more portions of ceph_setxattr() and ceph_removexattr() identical. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
All names defined in the directory and file virtual extended attribute tables are constant, and the size of each is known at compile time. So there's no need to compute their length every time any file's attribute is listed. Record the length of each string and use it when needed to determine the space need to represent them. In addition, compute the aggregate size of strings in each table just once at initialization time. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-