- 23 Oct, 2017 1 commit
-
-
Martin K. Petersen authored
Ever since it became possible to compile the SCSI core code as a module, the documentation describing the module parameters has been incorrect. Update the documentation to add a "scsi_mod." prefix to the relevant options. Reported-by: Laurence Oberman <loberman@redhat.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
- 19 Oct, 2017 12 commits
-
-
Viswas G authored
Corrected the value defined for LINKRATE_60 (6 Gig). Signed-off-by: Raj Dinesh <Raj.Dinesh@microsemi.com> Signed-off-by: Viswas G <viswas.g@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
when there's an error in 'ncq mode' the host has to read the ncq error log (10h) to clear the error state. however, the ccb that is setup for doing this doesn't setup the ccb so that the previous state is cleared. if the ccb was previously used for an IO n_elems is set and pm8001_ccb_task_free() treats this as the signal to go free a scatter-gather list (that's already been freed). Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
Modified SATA abort handling with following steps: 1) Set device state as recovery. 2) Send phy reset. 3) Wait for reset completion. 4) After successful reset, abort all IO's to the device. 5) After aborting all IO's to device, set device state as operational. Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
Added port reset timer value as 2000ms for PM8006 sata controller. Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
tag is taken from the tag pool instead of using the hardcoded tag value(1). Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
Different SAS addresses are assigned for each set of phys. Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
Added support to read ILA version and inactive firmware version from MPI configuration table and export through sysfs. Signed-off-by: Deepak Ukey <deepak.ukey@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Viswas G authored
sas_identify structure defined by pm80xx doesn't have CRC field. So added a new sas_identify structure without CRC. Signed-off-by: Raj Dinesh <Raj.Dinesh@microsemi.com> Signed-off-by: Viswas G <Viswas.G@microsemi.com> Acked-by: Jack Wang <jinpu.wang@profitbricks.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
As per SAM there is a status precedence, with any sense code 29/XX taking second place just after an ACA ACTIVE status. Additionally, each target might prefer to not queue any unit attention conditions, but just report one. Due to the above, this will be that one with the highest precedence. This results in the sense code 29/XX effectively overwriting any other unit attention. Hence we should report the power-on reset to userland so that it can take appropriate action. Signed-off-by: Hannes Reinecke <hare@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
Hitachi USP-V returns 'ILLEGAL FUNCTION' when the internal staging mechanism encountered an error. These errors should not be retried on another path. [mkp: s/invalid/illegal/] Signed-off-by: Hannes Reinecke <hare@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Kurt Garloff authored
All EMC SYMMETRIX support REPORT_LUNS, even if configured to report SCSI-2 for whatever reason. Signed-off-by: Kurt Garloff <garloff@suse.de> Signed-off-by: Hannes Reinecke <hare@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
- 18 Oct, 2017 2 commits
-
-
Hannes Reinecke authored
HITACHI is always supporting VPD pages, even though it's claiming to support SCSI Revision 3 only. Signed-off-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
The AIX VDASD devices do support VPD pages, but implement only SPC. So set BLIST_TRY_VPD_PAGES to correctly display the VPD information in sysfs. [mkp: typo] Signed-off-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
- 17 Oct, 2017 25 commits
-
-
weiping zhang authored
/sys/class/scsi_disk/0:2:0:0/manage_start_stop can be changed to 0 unexpectly by writing an invalid string. Signed-off-by: weiping zhang <zhangweiping@didichuxing.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
weiping zhang authored
/sys/class/scsi_disk/0:2:0:0/allow_restart can be changed to 0 unexpectedly by writing an invalid string such as the following: echo asdf > /sys/class/scsi_disk/0:2:0:0/allow_restart Signed-off-by: weiping zhang <zhangweiping@didichuxing.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
When checking the model and vendor string we need to use the minimum value of either string, otherwise we'll miss out on wildcard matches. And we should take care when matching with zero size strings; results might be unpredictable. With this patch the rules for matching devinfo strings are as follows: - Vendor strings must match exactly - Empty Model strings will only match if the devinfo model is also empty - Model strings shorter than the devinfo model string will not match Fixes: 5e7ff2ca ("SCSI: fix new bug in scsi_dev_info_list string matching") Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Alan Stern <stern@rowland.harvard.edu> Reviewed-by: Bart Van Assche <bart.vanassche@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
Reformat blacklist flags to make the values easier to read and to enhance error checking. Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Bart van Assche <bart.vanassche@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
Each scsi device is scanned according to the found blacklist flags, but this information is never presented to sysfs. This makes it quite hard to figure out if blacklisting worked as expected. With this patch we're exporting an additional attribute 'blacklist' containing the blacklist flags for this device. Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Bart Van Assche <bart.vanassche@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Hannes Reinecke authored
For testing purposes we need to be able to pass in the inquiry vendor and model. Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Bart Van Assche <bart.vanassche@wdc.com> Acked-by: Doug Gilbert <dgilbert@interlog.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Damien Le Moal authored
The three values starting at byte 8 of the Zoned Block Device Characteristics VPD page B6h are 32 bits values, not 64bits. So use get_unaligned_be32() to retrieve the values and not get_unaligned_be64() Fixes: 89d94756 ("sd: Implement support for ZBC devices") Cc: <stable@vger.kernel.org> Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Reviewed-by: Bart Van Assche <Bart.VanAssche@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Damien Le Moal authored
Instead of open coding, use the min() macro to calculate a report zones reply buffer length in sd_zbc_check_zone_size() and the round_up() macro for calculating the number of zones in sd_zbc_setup(). No functional change is introduced by this patch. Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Reviewed-by: Bart Van Assche <bart.vanassche@wdc.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Damien Le Moal authored
Rearrange sd_zbc_setup() to include use_16_for_rw and use_10_for_rw assignments and move the calculation of sdkp->zone_shift together with the assignment of the verified zone_blocks value in sd_zbc_check_zone_size(). No functional change is introduced by this patch. Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Bart Van Assche <Bart.VanAssche@wdc.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Damien Le Moal authored
Fix comments style (use kernel-doc style) and content to clarify some functions. Also fix some functions signature indentation and remove a useless blank line in sd_zbc_read_zones(). No functional change is introduced by this patch. Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Damien Le Moal authored
Move standard macro definitions for the zone types and zone conditions to scsi_proto.h together with the definitions related to the REPORT ZONES command. While at it, define all values in the enums to be clear. Also remove unnecessary includes in sd_zbc.c. No functional change is introduced by this patch. Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Reviewed-by: Bart Van Assche <Bart.VanAssche@wdc.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Reviewed-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Christoph Hellwig authored
Always use bsg_job->reply instead of scsi_req(bsg_job->req)->sense), as they always point to the same memory. Never set scsi_req(bsg_job->req)->result and we'll set that value through bsg_job_done. [mkp: applied by hand, fixed whitespace] Signed-off-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Reviewed-by: Himanshu Madhani <himanshu.madhani@cavium.com> Tested-by: Himanshu Madhani <himanshu.madhani@cavium.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Christoph Hellwig authored
As a user of bsg-lib the SAS transport should not poke into request internals but use the bsg_job fields instead. Signed-off-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Christoph Hellwig authored
bsg_job_done takes care of updating the scsi_request structure fields. Signed-off-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Christoph Hellwig authored
We already support 256 or more segments as long as the architecture supports SG chaining (all the ones that matter do), so removed the weird playing with limits from the job handler. Signed-off-by: Christoph Hellwig <hch@lst.de> Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Christos Gkekas authored
Remove redundant variables in quedi_fw.c that are set but not used. Signed-off-by: Christos Gkekas <chris.gekas@gmail.com> Acked-by: Manish Rangankar <Manish.Rangankar@cavium.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Giridhar Malavali authored
Based on the FC4 type, login will proceed to either FCP or FC-NVMe remote ports. Signed-off-by: Giridhar Malavali <giridhar.malavali@cavium.com> Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Himanshu Madhani authored
In some environments, user can choose to not enable SCSI-MQ but wants to use FC-NVMe feature of the driver. Since driver relies on Q-Pairs to allocate FC-NVMe resources, use existing module parameter to create Q-Pairs when FC-NVMe is enabled. Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Reviewed-by: Ewan D. Milne <emilne@redhat.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Himanshu Madhani authored
Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Duane Grigsby authored
If we discovered a topology that is N2N then we will issue a login to the target. If our WWPN is bigger than the target's WWPN then we will initiate login, otherwise we will just wait for the target to initiate login. [mkp: many whitespace errors] Signed-off-by: Duane Grigsby <duane.grigsby@cavium.com> Signed-off-by: Michael Hernandez <michael.hernandez@cavium.com> Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Tested-by: Ewan D. Milne <emilne@redhat.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Duane Grigsby authored
The MBC_GET_PORT_DATABASE command normally checks the port state information. This patch allows it to save that info in the fcport structure and ignore the check if the query flag is set. [mkp: typo] Signed-off-by: Duane Grigsby <duane.grigsby@cavium.com> Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Himanshu Madhani authored
Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Himanshu Madhani authored
[mkp: fixed whitespace] Signed-off-by: Himanshu Madhani <himanshu.madhani@cavium.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-
Dan Carpenter authored
The ! has higher precedence than the & operation. I've added parenthesis so this works as intended. Fixes: 952c303b ("scsi: lpfc: Ensure io aborts interlocked with the target.") Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
-