1. 09 Sep, 2014 6 commits
    • Simon Horman's avatar
      ARM: shmobile: r8a7740: Use SoC-specific 48-bit CMT compat string · a2ffcf87
      Simon Horman authored
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings for
      a number of drivers for Renesas hardware. The purpose of this patch is to
      make use of the SoC-specific CMT compat string for the r8a7740 48-bit CMT
      clock source.
      Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
      a2ffcf87
    • Simon Horman's avatar
      ARM: shmobile: r8a7779: Use SoC-specific TMU compat string · a51b7b38
      Simon Horman authored
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings for
      a number of drivers for Renesas hardware. The purpose of this patch is to
      make use of the SoC-specific CMT compat string for the r8a7779 TMU
      clock source.
      Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
      a51b7b38
    • Simon Horman's avatar
      ARM: shmobile: r8a7791: Use SoC-specific 48-bit CMT compat string · 4217f323
      Simon Horman authored
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings for
      a number of drivers for Renesas hardware. The purpose of this patch is to
      make use of the SoC-specific CMT compat string for the r8a7791 48-bit CMT
      clock source.
      Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
      4217f323
    • Simon Horman's avatar
      ARM: shmobile: r7s72100: Use SoC-specific MTU2 compat string · f401ce48
      Simon Horman authored
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings for
      a number of drivers for Renesas hardware. The purpose of this patch is to
      make use of the SoC-specific CMT compat string for the r7s72100 MTU2
      clock source.
      Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
      f401ce48
    • Simon Horman's avatar
      ARM: shmobile: r8a7790: Use SoC-specific 48-bit CMT compat string · 37757030
      Simon Horman authored
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings for
      a number of drivers for Renesas hardware. The purpose of this patch is to
      make use of the SoC-specific CMT compat string for the r8a7790 48-bit CMT
      clock source.
      Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
      37757030
    • Simon Horman's avatar
      Merge tag 'renesas-r8a7740-ccf-and-timers-for-v3.18' into dt-timers-for-v3.18 · dcc683ab
      Simon Horman authored
      Renesas ARM Based SoC R8a7740 CCF and Timers Updates for v3.18
      
      When booting using the r8a7740/armadillo800eva using dt-reference:
      * Use CCF to initialise clocks via DT
      * Initialise timers via DT
      dcc683ab
  2. 23 Aug, 2014 8 commits
  3. 17 Aug, 2014 8 commits
  4. 16 Aug, 2014 18 commits