- 23 Jun, 2012 4 commits
-
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The chip_id is not used. The voltage_base is not necessary, set base voltage to tps->desc.min_uV instead. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Mark Brown authored
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 22 Jun, 2012 2 commits
-
-
Axel Lin authored
Convert tps65910_ops and tps65910_ops_vdd3 to regulator_list_voltage_table. Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The min_uV and max_uV fields of struct tps_info are not used in the code. For the case voltage_table is provided, the min_uV and max_uV are the same values as volt_table[0] and volt_table[n_voltages -1]. For the case voltage_table is not available, having the min_uV and max_uV seems misleading. Current code uses equations to get the voltage value in this case, but these equations do not use the min_uV and max_uV fields of struct tps_info. Thus this patch removes the min_uV and max_uV fields from struct tps_info. Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 21 Jun, 2012 3 commits
-
-
Kim, Milo authored
Use err log rather than warning message when the platform data is NULL Signed-off-by: Milo(Woogyom) Kim <milo.kim@ti.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Mark Brown authored
Kconfig doesn't do the right thing for us here. Reported-by: Stephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Acked-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 20 Jun, 2012 5 commits
-
-
Mark Brown authored
The Wolfson Arizona platform is used for a range of low power audio hub CODECs. Many of these devices feature an integrated power supply for the microphone which is supported by this driver. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Return -EINVAL if pdata is NULL, otherwise we have NULL dereference bug. This patch also moves the code checking pdata earlier in lp872x_probe. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Yadwinder Singh Brar authored
This patch implements the .set_ramp_delay callback to set the ramp_delay on hardware for BUCK2/3/4 if ramp_delay is set in regulator constraints. This patch also do some cleaning work for unrequired members of struct max77686_data. Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Mark Brown authored
Fixes link failure due to devm_gpio_request_one() Reported-by: Stephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 19 Jun, 2012 7 commits
-
-
Kim, Milo authored
This driver supports TI/National LP8720, LP8725 PMIC. Signed-off-by: Milo(Woogyom) Kim <milo.kim@ti.com> Reviewed-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Sangbeom Kim authored
The S5M8767A can't know status of ap reset. So, After AP watchdog reset, AP can't boot normally. Problem can be happened like below condition. - AP Bootable lowest voltage(vdd_arm): 0.9v - AP DVFS voltage table: 0.8v, 0.9v, 1.0v - During AP works on lowest voltage(0.8V), watchdog reset is asserted - AP can't boot, because vdd arm is still 0.8v Solution - Basic concept: After ap watchdog reset, GPIO configuration is changed by default value - S5M8767A has function of voltage control with gpio (8 levels with 3 gpios) - Set bootable voltage on level 0 -> can work with default gpio configuration - In the probing, Change voltage control level from level 0 to level 1 - Execute normal dvfs operation on level 1 - After watchdog reset, ap gpio is set by default value - PMIC operation mode is changed by ap reset (level1 -> level0) - Regardless of previous vdd_arm voltage, AP always can be booted. Signed-off-by: Sangbeom Kim <sbkim73@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Yadwinder Singh Brar authored
This patch converts the driver to use regulator_set_voltage_time_sel() as .set_voltage_time_sel() callback. It also sets ramp_delay as 100000 uV/us for LDOs & normal BUCKs and 27500 uV/us(default/reset value) for BUCKs[2/3/4] in regulator_desc[]. Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
In current mapping table settings, min_uV/max_uV are always equal to volt_table[0] and volt_table[table_len -1]. Thus remove min_uV and max_uV from struct tps_info. The table based mapping with table_len == 1 means fixed voltage. So we don't need fixed flag to differentiate if it is fixed or not. This patch adds DCDC_FIXED_3300000_VSEL_table and DCDC_FIXED_1800000_VSEL_table for fixed voltage cases. So we can convert tps65023_dcdc_ops to regulator_list_voltage_table. This makes the code simpler. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
If .is_enabled callback is not implemented, regulator core assumes that the regulator is always on. Thus we don't need mc13xxx_sw_regulator_is_enabled function. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 18 Jun, 2012 5 commits
-
-
Mark Brown authored
Due to the lack of a generic clock API we'd had the 32kHz clock in the regulator driver but this is definitely a Linux-specific thing and now we have a clock API hopefully the code can be moved elsewhere. Try to avoid getting DTs deployed relying on the 32kHz clock by removing it from the bindings, grep seems to tell me it's not currently used anyway. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Mark Brown authored
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
This change makes it possible to set ramp_delay with 0.xxx mV/uS without truncation issue. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For table based mapping, we can calculate voltage difference by below equation: abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector]) Thus we can make regulator_set_voltage_time_sel work for table based mapping. regulator_set_voltage_time_sel() only supports linear or table based mapping. In case it is misused, also warn if neither linear nor table based mapping is used with regulator_set_voltage_time_sel(). Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
- 17 Jun, 2012 14 commits
-
-
Yadwinder Singh Brar authored
For some hardwares ramp_delay for BUCKs is a configurable parameter which can be configured through DT or board file.This patch adds ramp_delay to regulator constraints and allow user to configure it for regulators which supports this feature, through DT or board file. It will provide two ways of setting the ramp_delay for a regulator: First, by setting it as constraints in board file(for configurable regulators) and set_machine_constraints() will take care of setting it on hardware by calling(the provided) .set_ramp_delay() operation(callback). Second, by setting it as data in regulator_desc(as fixed/default ramp_delay rate) for a regulator in driver. regulator_set_voltage_time_sel() will give preference to constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly users should also take care accordingly while refering ramp_delay rate(in case of implementing their private .set_voltage_time_sel() callbacks for different regulators). [Rewrote subject for 80 columns -- broonie] Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The min_uV and max_uV are not really used in the code and misleading because the min_uV and max_uV settings does not match the value in the voltage table. For example, we have static const unsigned int ldo_vaux3_voltages[] = { 1200000, 1500000, 1800000, 2100000, 2500000, 2750000, 2790000, 2910000, }; With below min_uV/max_uV settings for AB8500_LDO_AUX3. .min_uV = 1100000, .max_uV = 3300000, The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2 and is wrong. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops because the voltage won't change. ( And ab8500_regulator_fixed_ops does not implement get_voltage_sel so set_voltage_time_sel won't be called ) Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0] falls with min_uV and max_uV. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
For fixed voltage, the n_voltages should be 1 rather than 0. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-
Axel Lin authored
Reuse map_voltage() to get the selector of a given uV. Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val(). Also remove unused wm8350_dcdc_val_to_mvolts() function. Signed-off-by: Axel Lin <axel.lin@gmail.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
-