Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
slapos
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Analytics
Analytics
CI / CD
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Titouan Soulard
slapos
Commits
dfb4cca5
Commit
dfb4cca5
authored
Feb 02, 2023
by
Jérome Perrin
Browse files
Options
Browse Files
Download
Plain Diff
Merge remote-tracking branch 'upstream/master' into zope4py2
parents
eeb887d7
a2272d7d
Changes
24
Expand all
Hide whitespace changes
Inline
Side-by-side
Showing
24 changed files
with
519 additions
and
296 deletions
+519
-296
software/ors-amarisoft/buildout.hash.cfg
software/ors-amarisoft/buildout.hash.cfg
+5
-5
software/ors-amarisoft/config/enb.jinja2.cfg
software/ors-amarisoft/config/enb.jinja2.cfg
+123
-124
software/ors-amarisoft/config/gnb.jinja2.cfg
software/ors-amarisoft/config/gnb.jinja2.cfg
+167
-167
software/ors-amarisoft/instance-enb-input-schema.json.jinja2
software/ors-amarisoft/instance-enb-input-schema.json.jinja2
+12
-0
software/ors-amarisoft/instance-enb.jinja2.cfg
software/ors-amarisoft/instance-enb.jinja2.cfg
+2
-0
software/ors-amarisoft/instance-gnb-input-schema.json.jinja2
software/ors-amarisoft/instance-gnb-input-schema.json.jinja2
+12
-0
software/ors-amarisoft/instance-gnb.jinja2.cfg
software/ors-amarisoft/instance-gnb.jinja2.cfg
+2
-0
software/ors-amarisoft/instance-tdd1900-enb-epc-input-schema.json
.../ors-amarisoft/instance-tdd1900-enb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd1900-enb-input-schema.json
...ware/ors-amarisoft/instance-tdd1900-enb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd1900-gnb-epc-input-schema.json
.../ors-amarisoft/instance-tdd1900-gnb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd1900-gnb-input-schema.json
...ware/ors-amarisoft/instance-tdd1900-gnb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd2600-enb-epc-input-schema.json
.../ors-amarisoft/instance-tdd2600-enb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd2600-enb-input-schema.json
...ware/ors-amarisoft/instance-tdd2600-enb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd2600-gnb-epc-input-schema.json
.../ors-amarisoft/instance-tdd2600-gnb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd2600-gnb-input-schema.json
...ware/ors-amarisoft/instance-tdd2600-gnb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3500-enb-epc-input-schema.json
.../ors-amarisoft/instance-tdd3500-enb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3500-enb-input-schema.json
...ware/ors-amarisoft/instance-tdd3500-enb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3500-gnb-epc-input-schema.json
.../ors-amarisoft/instance-tdd3500-gnb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3500-gnb-input-schema.json
...ware/ors-amarisoft/instance-tdd3500-gnb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3700-enb-epc-input-schema.json
.../ors-amarisoft/instance-tdd3700-enb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3700-enb-input-schema.json
...ware/ors-amarisoft/instance-tdd3700-enb-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3700-gnb-epc-input-schema.json
.../ors-amarisoft/instance-tdd3700-gnb-epc-input-schema.json
+12
-0
software/ors-amarisoft/instance-tdd3700-gnb-input-schema.json
...ware/ors-amarisoft/instance-tdd3700-gnb-input-schema.json
+12
-0
software/ors-amarisoft/instance.cfg
software/ors-amarisoft/instance.cfg
+4
-0
No files found.
software/ors-amarisoft/buildout.hash.cfg
View file @
dfb4cca5
...
...
@@ -16,7 +16,7 @@
[template]
filename = instance.cfg
md5sum =
61e9685d6aa973ae0c45c45ca357458a
md5sum =
ed72fb7c36b0bc046df177e4d6f3bf12
[amarisoft-stats.jinja2.py]
_update_hash_filename_ = amarisoft-stats.jinja2.py
...
...
@@ -28,7 +28,7 @@ md5sum = 833667743c693b8d5f78a2527b275a9e
[template-lte-enb]
_update_hash_filename_ = instance-enb.jinja2.cfg
md5sum =
afd8867c4dec5c5c68a4005dec502ebb
md5sum =
c4584b338d26f57d5c9384956be36677
[template-lte-gnb-epc]
_update_hash_filename_ = instance-gnb-epc.jinja2.cfg
...
...
@@ -40,7 +40,7 @@ md5sum = 99c05a34678adb5a70aa64ecf2ee4e35
[template-lte-gnb]
_update_hash_filename_ = instance-gnb.jinja2.cfg
md5sum =
cd0527037b7cb0ae53f2f822fcf551ac
md5sum =
954dd1409b0256874f9524a40b880e47
[template-lte-mme]
_update_hash_filename_ = instance-mme.jinja2.cfg
...
...
@@ -60,7 +60,7 @@ md5sum = dcaac06553a3222b14c0013a13f4a149
[enb.jinja2.cfg]
filename = config/enb.jinja2.cfg
md5sum =
1c9909f691b5bb00d3fc30d41613e26a
md5sum =
68ac87c7e3d2d3fb0e0601f83f949915
[sib23.asn]
filename = config/sib23.asn
...
...
@@ -68,7 +68,7 @@ md5sum = b377dac7f1fcf94fb9ce9ebed617f36a
[gnb.jinja2.cfg]
filename = config/gnb.jinja2.cfg
md5sum =
16698f0b4ea3e6cf40e9f070af2439e5
md5sum =
374a1943e400a908e1aee8e123683f6f
[ltelogs.jinja2.sh]
filename = ltelogs.jinja2.sh
...
...
software/ors-amarisoft/config/enb.jinja2.cfg
View file @
dfb4cca5
This diff is collapsed.
Click to expand it.
software/ors-amarisoft/config/gnb.jinja2.cfg
View file @
dfb4cca5
This diff is collapsed.
Click to expand it.
software/ors-amarisoft/instance-enb-input-schema.json.jinja2
View file @
dfb4cca5
...
...
@@ -161,6 +161,18 @@
"description": "Duration during which average temperature should not exceed specified threshold",
"type": "number",
"default": 600
},
"n_antenna_dl": {
"title": "Number of DL antennas",
"description": "Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port.",
"type": "number",
"default": {{ default_n_antenna_dl }}
},
"n_antenna_ul": {
"title": "Number of UL antennas",
"description": "Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port.",
"type": "number",
"default": {{ default_n_antenna_ul }}
}
}
}
software/ors-amarisoft/instance-enb.jinja2.cfg
View file @
dfb4cca5
...
...
@@ -45,6 +45,8 @@ configuration.default_lte_n_rb_dl = {{ default_lte_n_rb_dl }}
configuration.default_lte_tx_gain = {{ default_lte_tx_gain }}
configuration.default_lte_rx_gain = {{ default_lte_rx_gain }}
configuration.default_lte_inactivity_timer = {{ default_lte_inactivity_timer }}
configuration.default_n_antenna_dl = {{ default_n_antenna_dl }}
configuration.default_n_antenna_ul = {{ default_n_antenna_ul }}
[directory]
recipe = slapos.cookbook:mkdirectory
...
...
software/ors-amarisoft/instance-gnb-input-schema.json.jinja2
View file @
dfb4cca5
...
...
@@ -213,6 +213,18 @@
"description": "Duration during which average temperature should not exceed specified threshold",
"type": "number",
"default": 600
},
"n_antenna_dl": {
"title": "Number of DL antennas",
"description": "Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port.",
"type": "number",
"default": {{ default_n_antenna_dl }}
},
"n_antenna_ul": {
"title": "Number of UL antennas",
"description": "Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port.",
"type": "number",
"default": {{ default_n_antenna_ul }}
}
}
}
software/ors-amarisoft/instance-gnb.jinja2.cfg
View file @
dfb4cca5
...
...
@@ -45,6 +45,8 @@ configuration.default_nr_tx_gain = {{ default_nr_tx_gain }}
configuration.default_nr_inactivity_timer = {{ default_nr_inactivity_timer }}
configuration.default_nr_rx_gain = {{ default_nr_rx_gain }}
configuration.default_nr_ssb_pos_bitmap = {{ default_nr_ssb_pos_bitmap }}
configuration.default_n_antenna_dl = {{ default_n_antenna_dl }}
configuration.default_n_antenna_ul = {{ default_n_antenna_ul }}
[directory]
recipe = slapos.cookbook:mkdirectory
...
...
software/ors-amarisoft/instance-tdd1900-enb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -159,6 +159,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd1900-enb-input-schema.json
View file @
dfb4cca5
...
...
@@ -141,6 +141,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd1900-gnb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -211,6 +211,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd1900-gnb-input-schema.json
View file @
dfb4cca5
...
...
@@ -193,6 +193,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd2600-enb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -159,6 +159,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd2600-enb-input-schema.json
View file @
dfb4cca5
...
...
@@ -141,6 +141,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd2600-gnb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -211,6 +211,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd2600-gnb-input-schema.json
View file @
dfb4cca5
...
...
@@ -193,6 +193,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3500-enb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -159,6 +159,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3500-enb-input-schema.json
View file @
dfb4cca5
...
...
@@ -141,6 +141,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3500-gnb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -211,6 +211,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3500-gnb-input-schema.json
View file @
dfb4cca5
...
...
@@ -193,6 +193,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3700-enb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -159,6 +159,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3700-enb-input-schema.json
View file @
dfb4cca5
...
...
@@ -141,6 +141,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3700-gnb-epc-input-schema.json
View file @
dfb4cca5
...
...
@@ -211,6 +211,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance-tdd3700-gnb-input-schema.json
View file @
dfb4cca5
...
...
@@ -193,6 +193,18 @@
"description"
:
"Duration during which average temperature should not exceed specified threshold"
,
"type"
:
"number"
,
"default"
:
600
},
"n_antenna_dl"
:
{
"title"
:
"Number of DL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of DL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
},
"n_antenna_ul"
:
{
"title"
:
"Number of UL antennas"
,
"description"
:
"Enumeration: 1, 2, 4 or 8. Number of UL antennas. It must be the same for all NB-IoT and LTE cells sharing the same RF port."
,
"type"
:
"number"
,
"default"
:
2
}
}
}
software/ors-amarisoft/instance.cfg
View file @
dfb4cca5
...
...
@@ -124,6 +124,8 @@ extra-context =
raw default_lte_tx_gain ${default-params:default-lte-tx-gain}
raw default_lte_rx_gain ${default-params:default-lte-rx-gain}
raw default_lte_inactivity_timer ${default-params:default-lte-inactivity-timer}
raw default_n_antenna_dl ${default-params:default-n-antenna-dl}
raw default_n_antenna_ul ${default-params:default-n-antenna-ul}
raw min_frequency ${default-params:min-frequency}
raw max_frequency ${default-params:max-frequency}
...
...
@@ -154,6 +156,8 @@ extra-context =
raw default_nr_rx_gain ${default-params:default-nr-rx-gain}
raw default_nr_ssb_pos_bitmap ${default-params:default-nr-ssb-pos-bitmap}
raw default_nr_inactivity_timer ${default-params:default-nr-inactivity-timer}
raw default_n_antenna_dl ${default-params:default-n-antenna-dl}
raw default_n_antenna_ul ${default-params:default-n-antenna-ul}
raw min_frequency ${default-params:min-frequency}
raw max_frequency ${default-params:max-frequency}
raw python_path ${python3:location}
...
...
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment