regulator: dt-bindings: Add 'regulator-uv-less-critical-window-ms' property

Introduces a new devicetree property to specifies the time window (in
milliseconds) following a critical under-voltage (UV) event during which
less critical actions can be safely carried out by the system.

Less Critical Actions:
- Logging the under-voltage event for later analysis.
- Saving less critical data that may be useful for diagnosing issues or
  for audit purposes.

More Critical Actions (post the less critical window):
- Initiating procedures to properly shutdown hardware to prevent damage.

The 'regulator-uv-less-critical-window-ms' property is crucial for
conveying board-specific hardware characteristics, not for enforcing a
certain policy. The time window represented by this property is derived
from the physical attributes of the hardware like the capacity of
on-board capacitors, the power consumption of the components, and the
time needed to safely shut down hardware to prevent damage. These
attributes can significantly vary between different boards, making it a
board-specific property rather than a policy directive.

By providing a precise representation of the time available for less
critical actions post an under-voltage event, this property enables the
kernel to make informed decisions on action prioritization, ensuring
that essential preventative measures are taken to avoid hardware damage
while also allowing for data capture and analysis.
Signed-off-by: default avatarOleksij Rempel <o.rempel@pengutronix.de>
Acked-by: default avatarRob Herring <robh@kernel.org>
Link: https://lore.kernel.org/r/20231026144824.4065145-5-o.rempel@pengutronix.deSigned-off-by: default avatarMark Brown <broonie@kernel.org>
parent 633cd1c0
...@@ -186,6 +186,14 @@ properties: ...@@ -186,6 +186,14 @@ properties:
be enabled but limit setting can be omitted. Limit is given as microvolt be enabled but limit setting can be omitted. Limit is given as microvolt
offset from voltage set to regulator. offset from voltage set to regulator.
regulator-uv-less-critical-window-ms:
description: Specifies the time window (in milliseconds) following a
critical under-voltage event during which the system can continue to
operate safely while performing less critical operations. This property
provides a defined duration before a more severe reaction to the
under-voltage event is needed, allowing for certain non-urgent actions to
be carried out in preparation for potential power loss.
regulator-temp-protection-kelvin: regulator-temp-protection-kelvin:
description: Set over temperature protection limit. This is a limit where description: Set over temperature protection limit. This is a limit where
hardware performs emergency shutdown. Zero can be passed to disable hardware performs emergency shutdown. Zero can be passed to disable
......