-
Sean Paul authored
This patch adds a 70ms mystery delay to the bridge driver in enable. By experimentation, it seems like it can go anywhere up until we initiate semi-auto link training. If we don't have the delay, link training fails. I tried to root cause this as best I could, but neither the datasheet for the panel nor the bridge mention a delay of this magnitude in their timing requirements. So for now, add the mystery delay until someone figures out a better fix. Changes in v3: - Added to the set Cc: Sandeep Panda <spanda@codeaurora.org> Reviewed-by: Sandeep Panda <spanda@codeaurora.org> Signed-off-by: Sean Paul <seanpaul@chromium.org> Link: https://patchwork.freedesktop.org/patch/msgid/20180813213058.184821-8-sean@poorly.run
bf1178c9